1.
Plast Reconstr Surg ; 141(4S Sientra Shaped and Round Cohesive Gel Implants): 7S-19S, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29595714

RESUMO

BACKGROUND: In March 2012, the United States Food and Drug Administration approved Sientra's application for premarket approval of its portfolio of round and shaped silicone gel breast implants based on data from the largest silicone gel breast implant study to date. This article presents the results of Sientra's Core Study at the conclusion of 10 years. METHODS: The Sientra Core Study was a 10-year, open-label, prospective, multicenter clinical study designed to assess the safety and effectiveness of Sientra's breast implants in augmentation and reconstruction. A total of 1,788 patients (3,506 implants) were enrolled, including 1,116 primary augmentation, 363 revision-augmentation, 225 primary reconstruction, and 84 revision-reconstruction. RESULTS: Across all cohorts, the rate of rupture by patient was 8.6%, the rate of Baker grade III/IV capsular contracture was 13.5%, and the rate of reoperation was 31.5%. The rate of capsular contracture was statistically significantly lower for textured devices [9.0%; 95% confidence interval (CI), 7.0-11.5%] compared with smooth devices (17.5%; 95% CI, 14.9-20.4%). There were no cases of breast implant-associated anaplastic large cell lymphoma. Primary reasons for reoperations included capsular contracture (18.8%), and style/size change (19.3%), with over 50% of the reoperations due to cosmetic reasons. CONCLUSION: The 10-year results of Sientra's Core Study support a comprehensive safety and effectiveness profile of Sientra's portfolio of round and shaped breast implants.


Assuntos
Implante Mamário/efeitos adversos , Implantes de Mama/efeitos adversos , Contratura Capsular em Implantes/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Géis de Silicone/efeitos adversos , Adulto , Mama/cirurgia , Implante Mamário/instrumentação , Implante Mamário/estatística & dados numéricos , Implantes de Mama/estatística & dados numéricos , Feminino , Humanos , Contratura Capsular em Implantes/etiologia , Linfoma Anaplásico de Células Grandes/epidemiologia , Linfoma Anaplásico de Células Grandes/etiologia , Pessoa de Meia-Idade , Satisfação do Paciente , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Reoperação/estatística & dados numéricos , Propriedades de Superfície , Estados Unidos/epidemiologia , United States Food and Drug Administration
2.
Aesthet Surg J ; 36(4): 404-16, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26961987

RESUMO

BACKGROUND: Since approval in March 2012, data on Sientra's (Santa Barbara, CA) silicone gel implants have been updated and published regularly to provide immediate visibility to the continued safety and performance of these devices. The 9 year follow-up data support the previously published data confirming the ongoing safety and efficacy of Sientra silicone gel breast implants. OBJECTIVES: The authors provide updated 9 year study data for Sientra's round and shaped silicone gel breast implants. METHODS: The Core Study is an ongoing 10 year study that enrolled 1788 patients with 3506 Sientra implants across four indications (primary augmentation, revision-augmentation, primary reconstruction, and revision-reconstruction). For the safety analysis, Kaplan-Meier risk rates were calculated to evaluate postoperative complications, including all breast implant-related adverse effects. For the effectiveness analyses, results were presented through 8 years as patient satisfaction scores were assessed at even years. RESULTS: Through 9 years, the overall risk of capsular contracture was 12.6%. Smooth devices (16.6%, 95% CI, 14.2%, 19.5%) had a statistically significantly higher rate of capsular contracture compared to textured devices (8.0%, 95% CI, 6.2%, 10.4%). Out of the 610 reoperations in 477 patients, over half of all reoperations were due to cosmetic reasons (n = 315; 51.6%). Patient satisfaction remains high through 8 years, with 90% of primary augmentation patients indicating their breast implants look natural and feel soft. CONCLUSIONS: The 9-year follow-up data from the ongoing Core Study of the Sientra portfolio of HSC and HSC+ silicone gel breast implants reaffirm the very strong safety profile as well as continued patient satisfaction. LEVEL OF EVIDENCE: 2 Therapeutic.


Assuntos
Implante Mamário/instrumentação , Aprovação de Equipamentos , Adolescente , Adulto , Idoso , Implante Mamário/efeitos adversos , Implantes de Mama/efeitos adversos , Feminino , Seguimentos , Humanos , Contratura Capsular em Implantes/diagnóstico por imagem , Contratura Capsular em Implantes/etiologia , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Segurança do Paciente , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Géis de Silicone/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
3.
Plast Reconstr Surg ; 132(5): 1115-1123, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24056498

RESUMO

BACKGROUND: Although there are a few broadly agreed on contributory factors, the multifaceted causes of capsular contracture have remained unresolved for decades. This study investigates a variety of potential risk factors that contribute to capsular contracture in primary augmentation patients. METHODS: The data used for this analysis include 5109 implants in 2560 primary augmentation patients implanted by 34 surgeons based on 5-year results from Sientra's clinical study. Patients were evaluated at annual visits where the capsular contracture Baker grade was recorded. Potential risk factors, including patient attributes, implant attributes, surgery characteristics, pocket irrigation, and postsurgery characteristics, were analyzed using frequency and multivariate models. RESULTS: A total of 265 capsular contracture events in 179 patients were reported through 5 years. The overall Kaplan-Meier rate for capsular contracture was 7.6 percent by device. The unadjusted analysis showed increased odds of capsular contracture in smooth devices, periareolar incision, subglandular placement, antibiotic and steroid pocket irrigation, recommended massage, and surgical bra (p<0.05 for all). Results from the multivariate analysis, adjusting for all variables in the model, found six factors to be independently associated with capsular contracture (i.e., implant placement, implant surface, incision site, hematoma or seroma development, device size, and surgical bra; p<0.05 for all). CONCLUSION: This analysis has provided evidence that submuscular placement and textured implants, in addition to other factors, are significant in reducing the incidence of capsular contracture.


Assuntos
Implante Mamário/efeitos adversos , Implantes de Mama/efeitos adversos , Contratura Capsular em Implantes/etiologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Fatores de Risco , Adulto Jovem